Retained Percutaneous Foreign Body in the Wrist Managed Without C-arm Fluoroscopy Guidance: An Imaging Case Report from Zambia

Authors

  • Osward Bwanga Midland University Hospital Tullamore, Radiology Department https://orcid.org/0000-0002-3055-2303
  • Charity Nalwesha Lewanika General Hospital, Radiology Department, Zambia
  • Sibeso Kabeleka Lewanika General Hospital, Radiology Department, Zambia
  • Kennedy Chiyanda Lewanika General Hospital, Department of Surgery, Zambia
  • Eric Mwale Lewanika General Hospital, Department of Surgery, Zambia

DOI:

https://doi.org/10.55320/mjz.53.3.1081

Keywords:

Case report, C-arm, foreign body, radiography, surgical removal, Zambia

Abstract

Introduction: Retained percutaneous foreign bodies (FBs) are a common emergency and surgical problem. If not promptly identified and removed, FBs may lead to chronic pain, neurovascular injury, infection and medicolegal implications. Plain radiography remains the first-line imaging modality for detecting retained FBs.

Case presentation: A 24-year-old female presented with a small puncture wound following a needle-stick injury to the right hand/wrist. Radiographs confirmed a radiopaque FB projected over the midcarpal region adjacent to the capitate bone, with no evidence of intra-articular extension. Radiographic mapping guided surgical exploration, although two attempts were required before successful surgical removal. The patient was discharged in stable condition on the same day of FB removal. At the two-week follow-up, the wound had healed almost completely, with no complications observed.

Conclusion: This case highlights the importance of accurate localisation of a retained percutaneous foreign body for successful removal. Localisation should include orthogonal radiographs and skin-surface entry-site markers, with real-time image guidance where available. When C-arm fluoroscopy is unavailable, radiographic mapping can provide a practical preoperative localisation aid; however, because it relies on static images, localisation may be less precise and repeat surgical exploration may still be required.

Downloads

Download data is not yet available.

Published

30-09-2026

Issue

Section

Case Report

How to Cite

Bwanga, O., Nalwesha, C., Kabeleka, S., Chiyanda, K., & Mwale, E. (2026). Retained Percutaneous Foreign Body in the Wrist Managed Without C-arm Fluoroscopy Guidance: An Imaging Case Report from Zambia. Medical Journal of Zambia, 53(3), 523-529. https://doi.org/10.55320/mjz.53.3.1081